 2-line filters SIFI-F for normal insertion loss
250 V DC/AC, 50/60 Hz, 3 ... 36 A
Series/Type: Date: Version:
B84111F0000* 2008-08-07 07
(c) EPCOS AG 2008. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited.
2-line filters SIFI-F for normal insertion loss
B84111F0000*
Construction S 2-line filter S Metal case S Polyurethane potting (UL 94 V-0) Features S Optimized leakage current S Easy to install S Compact design S Cost-optimized construction S ENEC10, UL und cUL approval c us Applications S Switched-mode power supplies for - industrial electronics - telecom systems - data systems S DC applications S Medical engineering Type M Terminals S Filters up to 20A tab connectors 6.3 x 0.8 mm S Threaded studs M5 for filters from 25A to 36A Marking S Marking on component: manufacturer's logo, ordering code, rated voltage, rated current, rated temperature, climatic category, date code S Minimum marking on packaging: maufacturer's logo, ordering code, date code, quantity
Please read and Cautions and warnings and Important notes at the end of this document.
Page 2 of 14
B84111-F0000-*-07-7659
2-line filters SIFI-F for normal insertion loss
B84111F0000*
Typical circuit diagram of B84111F0000B* and B84111F0000G*
LINE
L
LOAD
L'
N
N'
Technical data and measuring conditions of B84111F0000B* and B84111F0000G* Rated voltage Rated frequency Test voltage line to line for 2 s Test voltage line to case for 2 s Leakage current Rated temperature Climatic category (IEC 60068-1) VR fR Utest Utest Ileak TR 250 50/60 1770 2700 At 230 V AC, 50 Hz 40 25/100/21 C V DC/AC Hz V DC V DC
Please read and Cautions and warnings and Important notes at the end of this document.
Page 3 of 14
B84111-F0000-*-07-7659
2-line filters SIFI-F for normal insertion loss
B84111F0000*
Typical circuit diagram of B84111F0000M* (for medical applications)
Line
L
Load
L'
N
N'
Technical data and measuring conditions of B84111F0000M* (for medical applications) Rated voltage Rated frequency Test voltage line to line for 2 s Test voltage line to case for 2 s Leakage current Rated temperature Climatic category (IEC 60068-1) VR fR Utest Utest Ileak TR 250 50/60 1770 2500 At 230 V AC, 50 Hz 40 25/100/21 C V DC/AC Hz V DC V AC
Please read and Cautions and warnings and Important notes at the end of this document.
Page 4 of 14
B84111-F0000-*-07-7659
2-line filters SIFI-F for normal insertion loss
B84111F0000*
Characteristics and ordering codes for B84111F0000B* and B84111F0000G* IR CR LR Ileak Approx. weight g Rtyp Ordering code Approvals
A 3 6 10 16 20 25 36
mH 2 x 0.1 F (X2) 2 x 1.5 2 x 4700 pF (Y2) 2 x 0.1 F (X2) 2 x 1.8 2 x 4700 pF (Y2)
mA
m 67 37 12.5 6.8 4.8 4.5 1.6 B84111F0000B030 B84111F0000B060 B84111F0000B110 B84111F0000B116 B84111F0000B120 B84111F0000G125 B84111F0000G136 X X X X X X X X X X X X X X X X X X X X X
< 0.5 90 < 0.5 90
2 x 0.1 F (X2) 2 x 0.87 < 0.5 90 2 x 4700 pF (Y2) 2 x 0.1 F (X2) 2 x 0.65 < 0.5 130 2 x 4700 pF (Y2) 2 x 0.1 F (X2) 2 x 0.43 < 0.5 130 2 x 4700 pF (Y2) 2 x 0.1 F (X2) 2 x 0.66 < 0.5 300 2 x 4700 pF (Y2) 2 x 0.47 F (X2) 2 x 10 nF (Y2) 2 x 0.4 <1 300
Characteristics and ordering codes for B84111F0000M* (for medical applications) IR CR LR Ileak A <2 <2 Approx. weight g 90 90 90 130 130 300 300 Rtyp Ordering code Approvals
A 3 6 10 16 20 25 36 2 x 0.1 F (X2) 2 x 0.1 F (X2) 2 x 0.1 F (X2) 2 x 0.1 F (X2) 2 x 0.1 F (X2) 2 x 0.1 F (X2) 2 x 0.47 F (X2)
mH 2 x 1.5 2 x 1.8
m 67 37 12.5 6.8 4.8 4.5 1.6 B84111F0000M030 X B84111F0000M060 X B84111F0000M110 B84111F0000M116 X X X X X X X X X X X X X X X X
2 x 0.87 < 2 2 x 0.65 < 2 2 x 0.43 < 2 2 x 0.66 < 2 2 x 0.4 <2
B84111F0000M120 X B84111F0000M125 X B84111F0000M136 X
X = approval granted
Please read and Cautions and warnings and Important notes at the end of this document.
Page 5 of 14
B84111-F0000-*-07-7659
2-line filters SIFI-F for normal insertion loss
B84111F0000*
Dimensional drawings B84111F0000*030 B84111F0000*060 B84111F0000*110
Marking
Tab connector DIN 46244-A6.3-0.8
all dimensions in mm !
Please read and Cautions and warnings and Important notes at the end of this document.
Page 6 of 14
B84111-F0000-*-07-7659
2-line filters SIFI-F for normal insertion loss
B84111F0000*
Dimensional drawings B84111F0000*116 B84111F0000*120
Marking
Tab connector DIN 46244-A6.3-0.8
all dimensions in mm !
Please read and Cautions and warnings and Important notes at the end of this document.
Page 7 of 14
B84111-F0000-*-07-7659
2-line filters SIFI-F for normal insertion loss
B84111F0000*
Dimensional drawings B84111F0000*125 B84111F0000*136
LINE
LOAD
Marking
Please read and Cautions and warnings and Important notes at the end of this document.
Page 8 of 14
B84111-F0000-*-07-7659
2-line filters SIFI-F for normal insertion loss
B84111F0000*
Insertion loss (typical values at Z = 50 W) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical)
B84111F0000B030 100 dB a 80 a 80 100 dB
B84111F0000B060
60 40 20
60 40 20
0 104
105
106
107 f
Hz 108
0 104
105
106
107 f
Hz 108
B84111F0000B110 100 dB a 80 a 80 100 dB
B84111F0000B116
60 40
60 40
20
20
0 104
105
106
107 f
Hz 108
0 104
105
106
107 f
Hz 108
Please read and Cautions and warnings and Important notes at the end of this document.
Page 9 of 14
B84111-F0000-*-07-7659
2-line filters SIFI-F for normal insertion loss
B84111F0000*
Insertion loss (typical values at Z = 50 W) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical)
B84111F0000B120 100 dB a 80 a 80 100 dB
B84111F0000G125
60 40
60 40
20
20
0 104
105
106
107 f
Hz 108
0 104
105
106
107 f
Hz 108
B84111F0000G136 100 dB a 80
60 40
20
0 104
105
106
107 f
Hz 108
Please read and Cautions and warnings and Important notes at the end of this document.
Page 10 of 14
B84111-F0000-*-07-7659
2-line filters SIFI-F for normal insertion loss
B84111F0000*
Insertion loss (typical values at Z = 50 W) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical)
B84111F0000M030 100 dB a 80 a 80 100 dB
B84111F0000M060
60 40 20
60 40 20
0 104
105
106
107 f
Hz 108
0 104
105
106
107 f
Hz 108
B84111F0000M110 100 dB a 80 a 80 100 dB
B84111F0000M116
60 40
60 40
20
20
0 104
105
106
107 f
Hz 108
0 104
105
106
107 f
Hz 108
Please read and Cautions and warnings and Important notes at the end of this document.
Page 11 of 14
B84111-F0000-*-07-7659
2-line filters SIFI-F for normal insertion loss
B84111F0000*
Insertion loss (typical values at Z = 50 W) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical)
B84111F0000M120 100 dB a 80 a 80 100 dB
B84111F0000M125
60 40 20
60 40
20
0 104
105
106
107 f
Hz 108
0 104
105
106
107 f
Hz 108
B84111F0000M136 100 dB a 80
60 40
20
0 104
105
106
107 f
Hz 108
Please read and Cautions and warnings and Important notes at the end of this document.
Page 12 of 14
B84111-F0000-*-07-7659
2-line filters SIFI-F for normal insertion loss
B84111F0000*
Caution and warnings S Please note the advices in our data book "EMC Filters" (latest edition); attention should be paid to the chapter "General safety notes". S It shall be ensured that only qualified persons (electricity specialists) are engaged on work such as planning, assembly, installation, operation, repair and maintenance. They must be provided with the corresponding documentation. S Danger of electric shock. EMC filters contain components that store an electric charge. Dangerous voltages can continue to exist at the filter terminals for longer than five minutes even after the power has been switched off. S The protective earth connections shall be the first to be made when the EMC filter is installed and the last to be disconnected. Depending on the magnitude of the leakage currents, the particular specifications for making the protective-earth connection must be observed. S Impermissible overloading of the EMC filter, such as with circuits able to cause resonances, impermissible voltages at higher frequencies etc. can lead to bodily injury and death as well as cause substantial material damages (e.g. destruction of the filter housing). S EMC filters must be protected in the application against impermissible exceeding of the rated currents by overcurrent protective. S In case of leakage currents > 3.5 mA you shall mount the PE conductor stationary with the required cross section before beginning of operation and save it against disconnecting. For leakage currents IL 4) < 10 mA the PE conductor must have a KU value 3) of 4.5; for leakage currents IL q 10 mA the PE conductor must have a KU value of 6.
3) The KU value (symbol KU) is a classification parameter of safety-referred failure types designed to ensure protection against hazardous body currents and excessive heating. A value of KU = 4.5 with respect to interruptions is attained: - with a permanently connected protective earth circuit w 1.5 mm2 - with a protective earth circuit w 2.5 mm2 connected via shroud connectors (IEC 60309-2). KU = 6 with respect to interruptions is achieved for fixed-connection lines w 10 mm2 where the type of connection and line layout correspond to the requirements for PEN conductors as specified in relevant standards. 4) IL = leakage current let-go
Please read and Cautions and warnings and Important notes at the end of this document.
Page 13 of 14
B84111-F0000-*-07-7659
2-line filters SIFI-F for normal insertion loss
B84111F0000*
Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statement cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of electronic components or failure before end of their usual service life time cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of a passive electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of a passive electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. 6. Unless otherwise agreed in individual contracts, all orders subject to the current version of the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSSP, CTVS, DSSP, MiniBlue, MKK, MLSC, MotorCAP, PCC, PhaseCap, PhaseMod, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks.
1
Please read and Cautions and warnings and Important notes at the end of this document.
Page 14 of 14
B84111-F0000-*-07-7659


▲Up To Search▲   

 
Price & Availability of B84111F0000B030

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X